32 research outputs found

    Spintronic magnetic anisotropy

    Full text link
    An attractive feature of magnetic adatoms and molecules for nanoscale applications is their superparamagnetism, the preferred alignment of their spin along an easy axis preventing undesired spin reversal. The underlying magnetic anisotropy barrier --a quadrupolar energy splitting-- is internally generated by spin-orbit interaction and can nowadays be probed by electronic transport. Here we predict that in a much broader class of quantum-dot systems with spin larger than one-half, superparamagnetism may arise without spin-orbit interaction: by attaching ferromagnets a spintronic exchange field of quadrupolar nature is generated locally. It can be observed in conductance measurements and surprisingly leads to enhanced spin filtering even in a state with zero average spin. Analogously to the spintronic dipolar exchange field, responsible for a local spin torque, the effect is susceptible to electric control and increases with tunnel coupling as well as with spin polarization.Comment: 6 pages with 4 figures + 26 pages of Supplementary Informatio

    Study Protocol: A Pilot Study to Determine the Safety and Efficacy of Induction-Therapy, De Novo MPA and Delayed mTOR-Inhibition in Liver Transplant Recipients with Impaired Renal Function. PATRON-Study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients undergoing liver transplantation with preexisting renal dysfunction are prone to further renal impairment with the early postoperative use of Calcineurin-inhibitors. However, there is only little scientific evidence for the safety and efficacy of de novo CNI free "bottom-up" regimens in patients with impaired renal function undergoing liver transplantation. This is a single-center study pilot-study (<b>PATRON07</b>) investigating safety and efficacy of CNI-free, "bottom-up" immunosuppressive (IS) strategy in patients undergoing liver transplantation (LT) with renal impairment prior to LT.</p> <p>Methods/Design</p> <p>Patients older than 18 years with renal impairment at the time of liver transplantation eGFR < 50 ml/min and/or serum creatinine levels > 1.5 mg/dL will be included. Patients in will receive a CNI-free combination therapy (basiliximab, MMF, steroids and delayed Sirolimus). Primary endpoint is the incidence of steroid resistant acute rejection within the first 30 days after LT. The study is designed as prospective two-step trial requiring a maximum of 29 patients. In the first step, 9 patients will be included. If 8 or more patients show no signs of biopsy proven steroid resistant rejection, additional 20 patients will be included. If in the second step a total of 27 or more patients reach the primary endpoint the regimen is regarded to be safe and efficient.</p> <p>Discussion</p> <p>If a CNI-free-"bottom-up" IS strategy is safe and effective, this may be an innovative concept in contrast to classic top-down strategies that could improve the patient short and long-time renal function as well as overall complications and survival after LT. The results of <b>PATRON07 </b>may be the basis for a large multicenter RCT investigating the new "bottom-up" immunosuppressive strategy in patients with poor renal function prior to LT.</p> <p><url>http://www.clinicaltrials.gov</url>-identifier: NCT00604357</p

    Effect of wood smoke exposure on vascular function and thrombus formation in healthy fire fighters

    Get PDF
    Background: Myocardial infarction is the leading cause of death in fire fighters and has been linked with exposure to air pollution and fire suppression duties. We therefore investigated the effects of wood smoke exposure on vascular vasomotor and fibrinolytic function, and thrombus formation in healthy fire fighters. Methods: In a double-blind randomized cross-over study, 16 healthy male fire fighters were exposed to wood smoke (~1 mg/m3 particulate matter concentration) or filtered air for one hour during intermittent exercise. Arterial pressure and stiffness were measured before and immediately after exposure, and forearm blood flow was measured during intra-brachial infusion of endothelium-dependent and -independent vasodilators 4–6 hours after exposure. Thrombus formation was assessed using the ex vivo Badimon chamber at 2 hours, and platelet activation was measured using flow cytometry for up to 24 hours after the exposure. Results: Compared to filtered air, exposure to wood smoke increased blood carboxyhaemoglobin concentrations (1.3% versus 0.8%; P &lt; 0.001), but had no effect on arterial pressure, augmentation index or pulse wave velocity (P &gt; 0.05 for all). Whilst there was a dose-dependent increase in forearm blood flow with each vasodilator (P &lt; 0.01 for all), there were no differences in blood flow responses to acetylcholine, sodium nitroprusside or verapamil between exposures (P &gt; 0.05 for all). Following exposure to wood smoke, vasodilatation to bradykinin increased (P = 0.003), but there was no effect on bradykinin-induced tissue-plasminogen activator release, thrombus area or markers of platelet activation (P &gt; 0.05 for all). Conclusions: Wood smoke exposure does not impair vascular vasomotor or fibrinolytic function, or increase thrombus formation in fire fighters. Acute cardiovascular events following fire suppression may be precipitated by exposure to other air pollutants or through other mechanisms, such as strenuous physical exertion and dehydration.Originally included in thesis in manuscript form.</p

    Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Clinimetric data for the fire fighting simulation test (FFST), a new test proposed for the Workers' Health Surveillance (WHS) of Dutch fire fighters, were evaluated.</p> <p>Methods</p> <p>Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC), and standard error of measurement (SEM), were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability.</p> <p>Results</p> <p>The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p < 0.05).</p> <p>Conclusions</p> <p>The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.</p
    corecore